Ablerex Products |
 |
|
|
|
|
| |
|
|
|
Product Summary
|
Troy |
|
|
|
|
| |
Troy Series (TR) |
|
|
| |
 |
Advanced Battery Discharge Management |
|
| |
 |
AVR Boost and Buck |
|
| |
 |
Built-in Self-diagnostics function |
|
| |
 |
Cold Start function |
|
| |
 |
Easy Swappable Battery Function |
|
| |
 |
Smart Microprocessor Control Design |
|
| |
 |
Smart RS232 Interface for Power Mangement |
|
| |
 |
Modem/LAN Internet Protection |
|
| |
 |
Site Wiring Fault Indicator |
|
| |
|
|
|
| |
Features |
|
|
|
Troy Series Compact but Powerful UPS
The Troy series, featured with smart microprocessor control design, AVR boost and buck, smart RS232 interface and cold start function, is a cost-effective solution to your mission-critical PC and valuable peripherals.
Advanced Battery Management prevents Deep-Discharge of the built-in battery during a power failure when the connected load is minimum.
AVR Boost and Buck automatically corrects either under-voltage or over-voltage conditions without unnecessary battery draining and extends the battery’s life.
Cold Start Function enables users to turn on the UPS without connecting to the Utility
Easy Swappable Battery Function may save your time and money by swapping the battery by yourself without sending it back for a factory service.
Smart Microprocessor Control Design integrates all power stages as well as control and communication functions that strongly enhance the functionality and reliability of the UPS.
Smart RS232 Interface for Power Management supports real-time power and UPS status monitoring, automatic shutdown, schedule and many other advance power management functions.
Easy Overload Recovery Push-button Circuit Breaker eliminates the need to change the broken fuse or return the UPS to the factory.
Site Wiring Fault Indicator immediately warns you of wiring problem such as improper grounding(115Vac system only).
Built-in Self-diagnostics Function may execute automatically upon power-on |
|
|
|
|
Model |
TR600 |
TR800 |
VTPro1000 |
VTPro
1500 |
|
INPUT |
|
Voltage Window |
85-140Vac or 162-290Vac |
115/230Vac+/-25% |
|
Frequency |
50/60Hz±5Hz
Auto-sensing |
|
OUTPUT |
|
Voltage |
AC
Mode |
Increase output 15%(input -9%~-25%) or Decrease
output 15%(input +9 ~ +25%) |
|
Inv.
Mode |
115 or 230Vac +/-10% |
|
Frequency |
50/60Hz ±1Hz |
|
Capacity (VA/W) |
600/300 |
800/400 |
1000/600 |
1500/900 |
|
Wave
Form |
Simulated Sine Wave |
|
Transfer Time |
4ms
typical |
|
Backup Time |
5~30 min. for typical PC Load |
|
DC
START |
Yes |
|
BATTERY |
|
Type
|
Sealed
Lead Acid Maintenance Free |
|
Capacity |
12V/7AH |
12V/9AH |
12V/7AH |
12V/9AH |
|
Quantity |
1pce |
2pcs |
|
Voltage |
12Vdc |
24Vdc |
|
Recharge Time |
8
hours to 90% |
|
DISPLAY |
|
LED
|
2 LEDs for Line/Backup and Battery Low/Fault |
4 LEDs for Line, Backup, Fault and Overload |
|
Self-Diagnostics |
Upon Power on and Software Control |
|
PROTECTION |
|
Overload |
AC
Mode |
>105% Buzzer continuously alarms |
|
Inv.
Mode |
>105%~<109% Buzzer continuously alarms
>110% UPS shuts immediately then alarms 5 seconds |
|
Short
Circuit |
AC
Mode |
Input Fuse & Electronic Circuit
|
|
Inv.
Mode |
Electronic Circuit |
|
ALARMS |
|
Audible and Visual |
Line Failure,
Battery Low, Overload and Fault Conditions |
|
PHYSICAL |
|
Dimensions
WxHxD (mm/inch) |
95x354x171mm(3.7”x13.9”x6.7”) |
147x360x234mm
(5.8”x14.2”x6.2”) |
|
Outlets
(NEMA/IEC) |
3
NEMA5-15R/3 IEC320-C13 |
4 NEMA5-15R/4 IEC320-C13 |
|
Net
Weight( kgs/lbs) |
7.0/15.5 |
7.5/16.5 |
13.0/28.6 |
16.0/32.5 |
|
ENVIRONMENT |
|
Operating
Temperature |
0 to 40
℃/ 32 to 104
℉ |
|
Temperature Warning |
The battery design life is based on a temperature of
25 C/77
℉,
Ambient temperature above this range will affect
battery life |
|
Humidity |
95% RH Maximum, Non-Condensing |
|
COMPUTER INTERFACE |
|
Interface Type |
RS232(USB Optional) |
USB(RS232 optional) |
|
Compatible Platforms |
Windows 95/98/NT/2000/XP/Vista, Novell Netware,
Linux, etc. |
|
SAFETY
CONFORMANCE |
|
Quality
Assurance |
ISO9001 Certified
|
|
Safety Standard |
EN62040-1-1 |
|
EMC
Standard |
EN62040-2, EN61000-3-2, EN61000-3-3,FCC Class A |
|
Marks |